Si2-Pro™

Si2-Pro™

22 499,00 € ex. VAT

  • 1280 × 720 video image resolution
  • 124 low-noise MEMS microphones, real-time sound visualization
  • Detect partial discharge from 0.3 m (1.0 ft) up to 200 m (656 ft)
View Product

Acoustic Measurement

124 low-noise MEMS microphones, real-time sound visualization

Severity Assessment

Automatic AI-based severity assessment including recommended actions onboard camera

Distance

From 0.3 m (1.0 ft) up to 200 m (656 ft)

Si2-PD™

Si2-PD™

17 499,00 € ex. VAT

  • 1280 × 720 video image resolution
  • 124 low-noise MEMS microphones, real-time sound visualization
  • Detect compressed air leaks, gas leaks, and partial discharges from 0.3 m (1.0 ft) up to 200 m (656 ft)
View Product

Acoustic Measurement

124 low-noise MEMS microphones, real-time sound visualization

Severity Assessment

Automatic AI-based severity assessment including recommended actions onboard camera

Distance

From 0.3 m (1.0 ft) up to 200 m (656 ft)

Si2-LD™

Si2-LD™

16 499,00 € ex. VAT

  • 1280 × 720 video image resolution
  • 124 low-noise MEMS microphones, real-time sound visualization
  • Detect compressed air leaks from 0.3 m (1.0 ft) up to 200 m (656 ft)
View Product

Acoustic Measurement

124 low-noise MEMS microphones, real-time sound visualization

Distance

From 0.3 m (1.0 ft) up to 200 m (656 ft)

Leak Rate

0.0032 l/min from 2.5 m (8.2 ft), 0.0044 l/min from 6 m (19.6 ft)

Acoustic Measurement

124 low-noise MEMS microphones, real-time sound visualization

Acoustic Measurement

124 low-noise MEMS microphones, real-time sound visualization

Acoustic Measurement

124 low-noise MEMS microphones, real-time sound visualization

Severity Assessment

Automatic AI-based severity assessment including recommended actions onboard camera

Severity Assessment

Automatic AI-based severity assessment including recommended actions onboard camera

Distance

From 0.3 m (1.0 ft) up to 200 m (656 ft)

Distance

From 0.3 m (1.0 ft) up to 200 m (656 ft)

Distance

From 0.3 m (1.0 ft) up to 200 m (656 ft)

Leak Rate

0.0032 l/min from 2.5 m (8.2 ft), 0.0044 l/min from 6 m (19.6 ft)

Resources & Support

Application Story

Příběh aplikace akustického zobrazování FLIR Si2 - snižování rostoucích účtů za energii

Application Story

FLIR Si2 akusztikus képalkotó alkalmazás története - Az emelkedő energiaszámlák csökkentése

Application Story

FLIR Si2 Acoustic Imaging Toepassingsverhaal - Verlaging van stijgende energierekeningen

Application Story

Historia zastosowania obrazowania akustycznego FLIR Si2 - obniżenie rosnących rachunków za energię

Tech Note

Technický list FLIR - Termovizní snímání pro monitorování stavu

Tech Note

Nota techniczna FLIR - obrazowanie termowizyjne do monitorowania stanu technicznego

Brochure

Wat wilt u meten? FLIR WDYNTM brochure

User Manual

FLIR Si2-Series User Manual

Application Story

FLIR Si2 Acoustic Imaging Application Story - Driving Down Rising Energy Bills

Warranty

FLIR Solutions Acoustic Camera Limited Warranty